GENTEC® 150/160 Series Manifold System is designed to supple High Purity Gas from one bank, then allow for manual switchover to the other bank after depletion of the bank. However, the switchover must be adjusted manually.
Features
• 150 Series manifold system uses R21 regulator for low flow systems
• 160 Series manifold system uses R22 regulator for high flow systems
• Dual line of cylinders avoid down time during cylinder change
• Diaphragm header valve on each side for cylinder changeover
• Piping is tested for pressure and leakage
• Optional wall mount
• Diaphragm station valves (1 per cylinder station)
• 3 foot stainless steel flex pigtail with integral check valve
EX: SL150 | A | 50 | D | 3L | 3R | C580 | S | 14 |
SERIES | LAYOUT**** | MAX. OUTLET PRESSURE | OUTLET CONNECTIONS | LEFT STATIONS | RIGHT STATIONS | INLET CONNECTIONS | PIGTAIL | OPTIONS |
SL150 | A: 12” standard | 50 psig | D: Diaphragm Valve 1/4" NPT(F) | 1 | 1 | C330: CGA330 | S: 316L | 1: Alarm |
SL160 |
| 100 psig | Leave blank for no valve | 2 | 2 | C350: CGA350 | T: Teflon | 2: Flashback Arrestors |
B150 | 250 psig |
| 3 | 3 | C510: CGA510 |
| 3: Filter | |
B160 | 500 psig (for SL150 only) | 4 | 4 | C540: CGA540 | R: Relief Valve | |||
5 | 5 | C580: CGA580 | Leave blank for no options | |||||
| C660: CGA660 | Can choose multiple options | ||||||
Other connections are available | ||||||||
| No Pigtail 00: 1/4"NPT(M) |
• Maximum Inlet pressure: 3000 psig
• Working temperature: -40˚F-140˚F (-40˚C-60˚C)
• Pipe: 1/2” seamless stainless steel (BA grade)
• Regulator leak rate: 2 x 10-9 scc/sec Helium R21
• Body: 316L Stainless Steel, Nickel-Plated Brass
• Diaphragm: 316L Stainless Steel
• Bonnet: 304, Nickel-Plated Brass
• Seat: PCTFE
• Spring: 316
• Research Laboratory
• Test Laboratory
• Manufacturing