GENTEC® R81SL Series Steam Heated Vaporizing Regulator is a diaphragm sensed single-stage regulator, is designed to heat and/or vaporize a gas or liquid sample before entering an analyzer system.
Features
• Metal-to-Metal Seal
• Intlet & Outlet Port Size: 1/4" NPT(F)
• Steam heating connection
• Intlet Port Size: 1/4" NPT(F)
• Outlet Port Size: 1/2" NPT(F)
EX: R81SL | A | V - | D | F | W - | 00 - | 00 |
Series | Body Ports | Seat | Inlet Pressure Ranges | Outlet Pressure Ranges | Gauge | Inlet Connections | Outlet Connections |
R81SL | A | V: Vespel® | B: 6000 psi (414 bar) | F: 0-500 psi (34 bar) | W: No Gauge | 00: 1/4" NPT(F) | 00: 1/4" NPT(F) |
| D: 3000 psi (206 bar) | G: 0-250 psi (17 bar) |
| 10: 1/8" GENLOK | 10: 1/8" GENLOK | ||
E: 1500 psi (104 bar) | I: 0-100 psi (7 bar) | 11: 1/4" GENLOK | 11: 1/4" GENLOK | ||||
| K: 0-50 psi (3 bar) | 15: 6 mm GENLOK | 15: 6 mm GENLOK | ||||
L: 0-25 psi (2 bar) | 19: 3 mm GENLOK | 19: 3 mm GENLOK | |||||
| Other connections available* | Other connections available* |
*For more connection options contact GENTEC®
• Maximum Inlet Pressure: 6000 psi (414 bar)
• Safety Test Pressure: 1.5 x Maximum Inlet Pressure
• Temperature Range: -40 to 500°F (-40 to 260°C)
• Inboard Leakage: 2 x 10-8 atm.cc/sec He
• Outboard Leakage: 2 x 10-8 atm.cc/sec He
• Maximum Cv: 0.06
• Weight: 2.9 lb (1.32 kg)
• Body: 316L Stainless Steel
• Bonnet: 316L Stainless Stee
• Seat: VESPEL®
• Diaphragm: 316L Stainless Steel
• Adjusting Knob: Stainless Steel
• Liquid Petroleum Analyzer
• Petrochemical / Refinery / Analyzer
• Sampling Systems